CAL2K Support Videos
Technical Support, Instructional Videos, Step-by-Step Help Videos
MASS ENTRY WITH THE CAL2K
In this video tutorial we will show you how to enter the sample mass manually on the CAL2K Isothermal Oxygen Bomb Calorimeter. Start by placing the empty crucible into the balance and zero the weight to the balance reads 0.0000g. Using the stainless steel tweezers, place one Benzoic Acid Tablet (or your sample) into the crucible and record the measured weight...
Watch on YouTubeRUNNING A CV WITH THE ECO CALORIMETER
A Basic Run through and step-by-step illustration on how to use the CAL2K ECO System.
Watch on YouTubeREPLACING THE CAL2K CALORIMETER DOOR SWITCH
Video tutorial on how to replace the calorimeter door switch. This applies to the CAL2k, e2k and ECO calorimeters from Digital Data Systems.
Watch on YouTubeHOW TO RUN A CV WITH THE CAL2K
In this video we go through the steps to run a calorific value sample with the CAL2K Oxygen Bomb Calorimeter System. Start by placing the crucible on the balance and tare it so the weight reads 0.0000g. Place one Benzoic Acid Tablet in the crucible to weigh. Enter the weight on the calorimeter automatically or manually.
Watch on YouTube3 STEPS FOR THE ECO CALORIMETER
How to enter the sample weight manually, calibrating the vessel and setting the un-linear factor. Enter the sample weight manually, Calibrate the vessel, Set the un-linear factor.
Watch on YouTubeCAL2K DRY STATIC JACKET BOMB CALORIMETER METHOD
We compare the CAL2K Dry Static Jacket Bomb Calorimetry method to the standard adiabatic bomb calorimetry method. The CAL2K method replaces the water jacket, stirrer and heater with an aluminium sleeve, built-in temperature sensors and an inner reaction vessel for fast and accurate calorific value determinations.
Watch on YouTubeSOLVING/PREVENTING A MISS FIRE WITH THE CAL2K
Solving/Preventing a Miss Fire with the CAL2K Isothermal Oxygen Bomb Calorimeter. The process in this video explains how to troubleshoot a miss fire and what tests to perform to prevent a miss fire from happening. For testing purposes we used an oxygen bomb vessel with the CAL2K Oxygen Bomb Calorimeter. The bomb vessel was inserted (without filling it with oxygen). The result was an "OPEN" message displayed on the LCD screen when the lid is closed.
Watch on YouTubeRUNNING A CV ON THE E2K CALORIMETER
A Basic Run through and step-by-step illustration on how to use the E2K Calorimeter System
Watch on YouTubeDETERMINE IF A VESSEL NEEDS RECONDITIONING
How to determine if a CAL2K Oxygen Bomb Calorimeter Bomb Vessel needs reconditioning.
Watch on YouTube