RESULT COMPENSATION | Automatically Applied | Automatically Applied | Automatically Applied | Automatically Applied | |
FEATURESspace&- | CAL3K-AP | CAL3K-A | CAL3K-F | CAL3K-S | CAL3K-ST |
BALANCE INTERFACE | Yes, from 2.4 to 38.4Kb | Yes, from 2.4 to 38.4Kb | Yes, from 2.4 to 38.4Kb | Yes, from 2.4 to 38.4Kb | Yes, from 2.4 to 38.4Kb |
RESULT MEMORY | 700 records | 700 records | 700 records | 480 records | 480 records |
TEMPERATURE RESOLUTION | 0.000'001°C | 0.000'001°C | 0.000'001°C | 0.000'001°C | 0.000'001°C |
DISPLAY | 4 x 40 character LCD | 4 x 40 character LCD | 4 x 40 character LCD | 2 x 24 character LCD / 4 x 40 character LCD | 4 x 40 character LCD |
KEYBOARD | QWERTY, External, PS2 | QWERTY, External, PS2 | QWERTY, External, PS2 | QWERTY, External, PS2 | QWERTY, External, PS2 |
SAMPLE ID | 16 characters, auto-increment | 16 characters, auto-increment | 16 characters, auto-increment | 16 characters, auto-increment | 16 characters, auto-increment |
GROUP ID | 16 characters | 16 characters | 16 characters | 16 characters | 16 characters |
REAL TIME | Yes | Yes | Yes | Yes | Yes |
CALIBRATION | 15 | 15 | 15 | 15 | 15 |
UNITS | KJ, KBTU, KCAL | KJ, KBTU, KCAL | KJ, KBTU, KCAL | KJ, KBTU, KCAL | KJ, KBTU, KCAL |
RESULT COMPENSATION | Automatically Applied | Automatically Applied | Automatically Applied | Automatically Applied | Automatically Applied |
VESSEL PRESS, MONITOR | Up to 100 bar | No | No | No | No |
OXYGEN FILLING | Internal, automatic filling | External manual filling station | External manual filling station | External manual filling station | External manual filling station |
DE-FILLING | Automatic | Manual | Manual | Manual | Manual |
MAX CHASSIS RECORDING | Yes | Yes | Yes | Yes | Yes |
CHASSIS NAME | 16 Characters, Bluetooth name | 16 Characters, Bluetooth name | 16 Characters, Bluetooth name | 16 Characters, Bluetooth name | 16 Characters, Bluetooth name |
KEYWORD PASSWORD | DDS3K | DDS3K | DDS3K | DDS3K | DDS3K |
VESSEL LEAK MONITOR | Yes, flags results and warning | No | No | No | No |
VESSEL LOCKOUT | Yes, 5000 firings | Yes, 5000 firings | Yes, 5000 firings | Yes, 5000 firings | Yes, 5000 firings |
SAMPLE REPEAT SPEED | 6 min | 4 - 5 min | 7 - 8 min | 20 min | 20 min |
OPERATOR TIME PER TEST | +/- 3 min | +/- 3 min | +/- 3 min | +/- 3 min | +/- 3 min |
COOLING | Air | Air | Air | Built-in | Built-in |
COOLING MODES | Ambient/ Fixed | Ambient/ Fixed | Ambient/ Fixed | Ambient/ Fixed | Ambient/ Fixed |
RSD | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 |
POWER CONSUMPTION | 12W | 12W | 6W | 6W | 6W |
POWER SUPPLY | External 12V | External 12V | External 12V | External 12V | External 12V |
WATER CONSUMPTION | None | None | None | None | None |
REPEATABILITY | 0.10% | 0.10% | 0.10% | 0.10% | 0.10% |
OPERATING MODES | Dynamic, Isothermal, Adiabatic | Dynamic, Isothermal, Adiabatic | Dynamic | Dynamic | Dynamic |
NUMBER OF VESSELS | 4 | 4 | 4 | 1 | 2 |
CLOSURE TYPE | Screw (Thread) Cap | Screw (Thread) Cap | Screw (Thread) Cap | Screw (Thread) Cap | Screw (Thread) Cap |
TESTS P/H WITH 2 VESSELS | 8+ | 10+ | 4-6+ | 2 | 3+ |
BOMB VESSEL TYPE | Removable | Removable | Removable | Removable | Removable |
BOMB VESSEL WASHING | Manual | Manual | Manual | Manual | Manual |
PRINTER CONNECTION | RS232 | RS232 | RS232 | RS232 | RS232 |
BALANCE CONNECTION | RS232 | RS232 | RS232 | RS232 | RS232 |
ENVIRONMENTAL | 5-40°C | 5-40°C | 5-40°C | 5-40°C | 5-40°C |
PRINTING OF RESULTS | Via PC Software or RS232 Printer | Via PC Software or RS232 Printer | Via PC Software or RS232 Printer | Via PC Software or RS232 Printer | Via PC Software or RS232 Printer |
PC SOFTWARE | Advanced | Advanced | Advanced | Advanced | Advanced |
CORRECTION FACTORS | 4 | 4 | 4 | 4 | 4 |
MASS ENTRY | Auto & Manual | Auto & Manual | Auto & Manual | Auto & Manual | Auto & Manual |
CE/ TUV CERTIFICATE | Yes (Pending) | Yes (Pending) | Yes | Yes | Yes (Pending) |
VESSEL DETERMINATIONS | Typically 25000 firings (Depending on sample type and maintenance) | Typically 25000 firings (Depending on sample type and maintenance) | Typically 25000 firings (Depending on sample type and maintenance) | Typically 25000 firings (Depending on sample type and maintenance) | Typically 25000 firings (Depending on sample type and maintenance) |
SPIKING | Yes | Yes | Yes | Yes | Yes |
SELF TESTING | Yes | Yes | Yes | Yes | Yes |
CONNECTIVITY | USB 2.0, 2 x RS232 at 115.2 KB for Bluetooth | USB 2.0, 2 x RS232 at 115.2 KB for Bluetooth | USB 2.0, 2 x RS232 at 115.2 KB for Bluetooth | 2 x RS232 at 115.2 KB for Bluetooth | 2 x RS232 at 115.2 KB for Bluetooth |
PRINTING | Yes, D1 port, 1.2 to 115.2KB | Yes, D1 port, 1.2 to 115.2KB | Yes | Yes | Yes |
MOISTURE COMPENSATION | Yes | Yes | Yes | Yes | Yes |
FOOD FIBER COMPENSATION | Yes | Yes | Yes | Yes | Yes |
RESULT APPROVAL | Yes, Keyboard or PC | Yes, Keyboard or PC | Yes, Keyboard or PC | Yes, Keyboard or PC | Yes, Keyboard or PC |
REAL TIME PRINTOUT | Yes, optional as toner and parameter header | Yes, optional as toner and parameter header | Yes, optional as toner and parameter header | No | No |
GELATIN CAPSULE COMPATIBLE | Yes | Yes | Yes | Yes | Yes |
*Please note that specifications are subject to change at any time. Please consult your agent.
**Please read the instruction manual provided with your product carefully when operating the system.
-
FEATURESspace&- CAL3K-AP MASS HEAP No BALANCE INTERFACE Yes, from 2.4 to 38.4Kb RESULT MEMORY 1024 records, 262KB TEMPERATURE RESOLUTION 0.000'001°C DISPLAY 4 x 40 character LCD KEYBOARD QWERTY, External, PS2 SAMPLE ID 16 characters, auto-increment GROUP ID 16 characters VESSEL RECORD Yes, unlimited REAL TIME Yes CHASSIS IDENTIFICATION Yes, number CALIBRATION Average over 15, replacing the oldest or not used HISTORY CALIBRATION Average from last 15 UNITS KJ, BTU, CAL RESULT COMPENSATION Automatically Applied RESULT VALIDATION Yes VESSEL PRESS, MONITOR Up to 100 bar OXYGEN FILLING Automatic DE-FILLING Automatic MAX CHASSIS RECORDING Yes CHASSIS NAME 20 characters, Bluetooth name PASSWORD CAL3K & PC Password NETWORK MULTIPLE CALORIMETERS No VESSEL LEAK MONITOR Yes, flags results and warning VESSEL LOCKOUT, LOCK-IN Yes, Manual/ Auto Linking SAMPLE REPEAT SPEED 6 min OPERATOR TIME PER TEST +/- 3 min COOLING Air COOLING MODES Ambient/ Fixed RSD 0.1 POWER CONSUMPTION 0-264 VAC 12W POWER SUPPLY External 12V WATER CONSUMPTION None REPEATABILITY 0.1% CALORIMETER TYPE Dynamic, Isothermal, Adiabatic NUMBER OF VESSELS Unlimited CLOSURE TYPE Bayonet Lid TESTS P/H WITH 2 VESSELS 8 - 9 BOMB VESSEL TYPE Removable BOMB VESSEL WASHING Manual PRINTER CONNECTION RS232 BALANCE CONNECTION RS232 ENVIRONMENTAL 5-40°C PRINTING OF RESULTS Via PC Software & RS232 Printer PC SOFTWARE Advanced CORRECTION FACTORS 4 MASS ENTRY Auto & Manual CE/ TUV CERTIFICATE Yes (Pending) VESSEL DETERMINATIONS Unlimited SPIKING Yes SELF TESTING Yes CONNECTIVITY USB 2.0, 2 x RS232 at 115.2 KB for Bluetooth STATS Yes PRINTING Yes, D1 port, 1.2 to 115.2KB MOISTURE COMPENSATION Yes FOOD FIBER COMPENSATION Yes LIMS Yes RESULT APPROVAL Yes, Keyboard or PC REAL TIME PRINTOUT Yes, optional as toner and parameter header GELATINE CAPSULE Yes *Please note that specifications are subject to change at any time. Please consult your agent.
**Please read the instruction manual provided with your product carefully when operating the system.
-
FEATURESspace&- CAL3K-A MASS HEAP No BALANCE INTERFACE Yes, from 2.4 to 38.4Kb RESULT MEMORY 1024 records, 262KB TEMPERATURE RESOLUTION 0.000'001°C DISPLAY 4 x 40 character LCD KEYBOARD QWERTY, External, PS2 SAMPLE ID 16 characters, auto-increment GROUP ID 16 characters VESSEL RECORD Yes, unlimited REAL TIME Yes CHASSIS IDENTIFICATION Yes, number CALIBRATION Average over 15, replacing the oldest or not used HISTORY CALIBRATION Average from last 15 UNITS KJ, BTU, CAL RESULT COMPENSATION Automatically Applied RESULT VALIDATION Yes VESSEL PRESS, MONITOR Up to 100 bar OXYGEN FILLING Automatic DE-FILLING Automatic MAX CHASSIS RECORDING Yes CHASSIS NAME 20 characters, Bluetooth name PASSWORD CAL3K & PC Password NETWORK MULTIPLE CALORIMETERS No VESSEL LEAK MONITOR Yes, flags results and warning VESSEL LOCKOUT, LOCK-IN Yes, Manual/ Auto Linking SAMPLE REPEAT SPEED 6 min OPERATOR TIME PER TEST +/- 3 min COOLING Air COOLING MODES Ambient/ Fixed RSD 0.1 POWER CONSUMPTION 0-264 VAC 12W POWER SUPPLY External 12V WATER CONSUMPTION None REPEATABILITY 0.1% CALORIMETER TYPE Dynamic, Isothermal, Adiabatic NUMBER OF VESSELS Unlimited CLOSURE TYPE Bayonet Lid TESTS P/H WITH 2 VESSELS 8 - 9 BOMB VESSEL TYPE Removable BOMB VESSEL WASHING Manual PRINTER CONNECTION RS232 BALANCE CONNECTION RS232 ENVIRONMENTAL 5-40°C PRINTING OF RESULTS Via PC Software & RS232 Printer PC SOFTWARE Advanced CORRECTION FACTORS 4 MASS ENTRY Auto & Manual CE/ TUV CERTIFICATE Yes (Pending) VESSEL DETERMINATIONS Unlimited SPIKING Yes SELF TESTING Yes CONNECTIVITY USB 2.0, 2 x RS232 at 115.2 KB for Bluetooth STATS Yes PRINTING Yes, D1 port, 1.2 to 115.2KB MOISTURE COMPENSATION Yes FOOD FIBER COMPENSATION Yes LIMS Yes RESULT APPROVAL Yes, Keyboard or PC REAL TIME PRINTOUT Yes, optional as toner and parameter header GELATINE CAPSULE Yes *Please note that specifications are subject to change at any time. Please consult your agent.
**Please read the instruction manual provided with your product carefully when operating the system.
-
FEATURESspace&- CAL3K-F MASS HEAP No BALANCE INTERFACE Yes, from 2.4 to 38.4Kb RESULT MEMORY 300 records TEMPERATURE RESOLUTION 0.000'001°C DISPLAY 4 x 40 character LCD KEYBOARD QWERTY, External, PS2 SAMPLE ID 16 characters, auto-increment GROUP ID 16 characters VESSEL RECORD Yes, limited REAL TIME Yes CHASSIS IDENTIFICATION Yes CALIBRATION Average over 15, replacing the oldest or not used HISTORY CALIBRATION Average from last 15 UNITS KJ, BTU, CAL RESULT COMPENSATION Automatically Applied RESULT VALIDATION Yes VESSEL PRESS, MONITOR No OXYGEN FILLING Manual DE-FILLING Manual MAX CHASSIS RECORDING Yes CHASSIS NAME - PASSWORD CAL3K & PC Password NETWORK MULTIPLE CALORIMETERS No VESSEL LEAK MONITOR No VESSEL LOCKOUT, LOCK-IN Yes, Manual/ Auto Linking SAMPLE REPEAT SPEED 7 - 8 min OPERATOR TIME PER TEST +/- 3 min COOLING Air COOLING MODES Ambient/ Fixed RSD 0.1 POWER CONSUMPTION 12 VAC 6W POWER SUPPLY External 12V WATER CONSUMPTION None REPEATABILITY 0.1% CALORIMETER TYPE Dynamic NUMBER OF VESSELS Unlimited CLOSURE TYPE Bayonet Lid TESTS P/H WITH 2 VESSELS 4-6 BOMB VESSEL TYPE Removable BOMB VESSEL WASHING Manual PRINTER CONNECTION RS232 BALANCE CONNECTION RS232 ENVIRONMENTAL 5-40°C PRINTING OF RESULTS Via PC Software & RS232 Printer PC SOFTWARE Advanced CORRECTION FACTORS 4 MASS ENTRY Auto & Manual CE/ TUV CERTIFICATE Yes VESSEL DETERMINATIONS Unlimited SPIKING Yes SELF TESTING Yes CONNECTIVITY USB 2.0, 2 x RS232 at 115.2 KB STATS Yes PRINTING Yes MOISTURE COMPENSATION Yes FOOD FIBER COMPENSATION Yes LIMS Yes RESULT APPROVAL Yes, Keyboard or PC REAL TIME PRINTOUT Yes, optional as toner and parameter header GELATINE CAPSULE Yes *Please note that specifications are subject to change at any time. Please consult your agent.
**Please read the instruction manual provided with your product carefully when operating the system.
-
FEATURESspace&- CAL3K-S MASS HEAP No BALANCE INTERFACE Yes, from 2.4 to 38.4Kb RESULT MEMORY 300 records TEMPERATURE RESOLUTION 0.000'001°C DISPLAY 4 x 20 character LCD KEYBOARD QWERTY, External, PS2 SAMPLE ID 16 characters, auto-increment GROUP ID - VESSEL RECORD Yes, limited REAL TIME Yes CHASSIS IDENTIFICATION Yes CALIBRATION Average over 15, replacing the oldest or not used HISTORY CALIBRATION Average from last 15 UNITS KJ, BTU, CAL RESULT COMPENSATION Automatically Applied RESULT VALIDATION Yes VESSEL PRESS, MONITOR No OXYGEN FILLING Manual DE-FILLING Manual MAX CHASSIS RECORDING Yes CHASSIS NAME - PASSWORD CAL3K & PC Password NETWORK MULTIPLE CALORIMETERS No VESSEL LEAK MONITOR No VESSEL LOCKOUT, LOCK-IN Yes, Manual/ Auto Linking SAMPLE REPEAT SPEED 30 min OPERATOR TIME PER TEST +/- 3 min COOLING Built-in COOLING MODES Ambient/ Fixed RSD 0.1 POWER CONSUMPTION 12 VAC 6W POWER SUPPLY External 12V WATER CONSUMPTION None REPEATABILITY 0.1% CALORIMETER TYPE Dynamic NUMBER OF VESSELS Limited (1) CLOSURE TYPE Screw Cap (thread) TESTS P/H WITH 2 VESSELS 1 - 2 Sample with 1 Vessel Only BOMB VESSEL TYPE Removable BOMB VESSEL WASHING Manual PRINTER CONNECTION RS232 BALANCE CONNECTION RS232 ENVIRONMENTAL 5-40°C PRINTING OF RESULTS Via PC Software & RS232 Printer PC SOFTWARE Advanced CORRECTION FACTORS 4 MASS ENTRY Auto & Manual CE/ TUV CERTIFICATE Yes VESSEL DETERMINATIONS 5000 SPIKING Yes SELF TESTING Yes CONNECTIVITY USB 2.0, 2 x RS232 at 115.2 KB STATS Yes PRINTING Yes MOISTURE COMPENSATION Yes FOOD FIBER COMPENSATION Yes LIMS Yes RESULT APPROVAL Yes, Keyboard or PC REAL TIME PRINTOUT - GELATINE CAPSULE Yes *Please note that specifications are subject to change at any time. Please consult your agent.
**Please read the instruction manual provided with your product carefully when operating the system.